Data readiness · before the claim
Enabled
Renders now on Henriksvej 7's data.
70/100
Data confidence
- Required data 10/10 in place
- Ideal data 0/3 in place
Tariff-aware ranking + EPC-grade classifier sharpen which bundle to recommend (method: internal).
The plan in one line
Rated D today. A credible path to C.
One bounded set of window upgrades, about 100-128k kr. Below: exactly what it includes, what changes for the owner, and the checks behind every number.
130,6 kWh/m²/år
Today
116,8 kWh/m²/år
After upgrades
Possible result from the current energy data. This is not a certified future label until an energy expert reviews it.
The move
Replace the original windows, in stages.
One bounded set of work, no structural surprises. It is the single change that moves the label and the comfort together, and it can be staged room by room before a sale.
Compare three options → Get quotes for this work →100-128k
kr. · expected cost of the recommended upgrade
- Energy reduction
- −11% · -13,8 kWh/m²/år
- Work items
- 10
- Financial payback
- Comfort-led, not an investment: simple payback is long (54 år payback estimate). The value is a clearer sale, not a return.
-
Windows
10 items11,9 m² · ≈-13,8 kWh/m²/år
100.041 kr.-127.830 kr.
View 10 work items
-
Udskiftning af eksisterende dannebrogsvinduer
Vinduer · 3,5 m² · U 2,2 -> 0,8
19.987 kr.-25.539 kr.
-
Udskiftning af eksisterende dannebrogsvinduer
Vinduer · 1,6 m² · U 2,2 -> 0,8
9.274 kr.-11.850 kr.
-
Udskiftning af eksisterende dannebrogsvinduer
Vinduer · 1,3 m² · U 2,2 -> 0,8
14.976 kr.-19.136 kr.
-
Udskiftning af eksisterende dannebrogsvinduer
Vinduer · 1,2 m² · U 2,2 -> 0,8
13.997 kr.-17.885 kr.
-
Udskiftning af eksisterende dannebrogsvinduer
Vinduer · 1 m² · U 2,2 -> 0,8
16.589 kr.-21.197 kr.
-
Udskiftning af eksisterende enkeltfagsvinduer i fast ramme
Vinduer · 0,7 m² · U 2,8 -> 0,8
6.966 kr.-8.901 kr.
-
Udskiftning af eksisterende enkeltfagsvinduer i fast ramme
Vinduer · 0,6 m² · U 2,8 -> 0,8
3.456 kr.-4.416 kr.
-
Udskiftning af eksisterende enkeltfagsvinduer i fast ramme
Vinduer · 0,6 m² · U 2,8 -> 0,8
3.402 kr.-4.347 kr.
-
Udskiftning af eksisterende dannebrogsvinduer
Vinduer · 0,9 m² · U 2,2 -> 0,8
5.184 kr.-6.624 kr.
-
Udskiftning af eksisterende enkeltfagsvinduer i fast ramme
Vinduer · 0,6 m² · U 2,8 -> 0,8
6.210 kr.-7.935 kr.
-
On your actual scan
The 14 windows, located on the 3D model.
Each green marker is a real window from the scan, fused with the Be18 energy proposal: the current U-value comes from the surface model, the target from the plan. Pick a floor and click a marker to read it.
- Windows located
- 14
- Glass area
- 19 m²
- U-value
- 2,4 → 0,8 W/m²K
- Floors
- Basement (4) · Ground floor (8) · First floor (2)
3D inspection
Room evidence map
Ground floor · 8 annotations · 54 components
What it changes
Comfort first. The sale follows.
- 01
Warmer in winter
New windows cut heat loss at the largest openings in the house.
- 02
Less label concern
A bounded, costed path instead of vague label-D uncertainty at the viewing.
- 03
Quieter rooms
Sealed, modern glazing noticeably lowers street noise.
- 04
Clearer disclosure
The plan sits beside the inspection report, never instead of it.
Already on the register
There is already an open building permit.
Permit
S2025-2875
dated 14-04-2025
BBR records an open building case (S2025-2875) with a permit dated 14-04-2025 and construction logged for 2026. Stage this energy-upgrade plan around that work — windows, envelope and heating are cheapest to touch while the site is already open, and a single Byg-og-Miljø filing can carry both.
Source: BBR byggesager (construction_cases)
Why you can trust it
Every number traces to measured data.
Annex VIII readiness
6/12 ready
2 need review · 2 missing input · 2 rules pending.
Measured areas
- Floor
- 155 m²
- Wall
- 368 m²
- Ceiling
- 177 m²
One honest caveat
This is a possible result from current energy data, not a certified future label until an energy expert reviews it. Heated area has a disclosed conflict .
Sources
4-
Source data - Be18 XML energy label 100103025
-
Energy calculation file -
Energy calculation run