Henriksvej 7

2400 København NV

Renovation plan · Henriksvej 7

Energy upgrade plan

Data readiness · before the claim

Enabled

Renders now on Henriksvej 7's data.

70/100

Data confidence

Required data 10/10 in place
Ideal data 0/3 in place
Next best input Deepen the underlying model +14 → 84 · unlocks 15 artefacts

Tariff-aware ranking + EPC-grade classifier sharpen which bundle to recommend (method: internal).

The plan in one line

Rated D today. A credible path to C.

One bounded set of window upgrades, about 100-128k kr. Below: exactly what it includes, what changes for the owner, and the checks behind every number.

D

130,6 kWh/m²/år

Today

C

116,8 kWh/m²/år

After upgrades

Possible result from the current energy data. This is not a certified future label until an energy expert reviews it.

The move

Replace the original windows, in stages.

One bounded set of work, no structural surprises. It is the single change that moves the label and the comfort together, and it can be staged room by room before a sale.

Compare three options → Get quotes for this work →

100-128k

kr. · expected cost of the recommended upgrade

Energy reduction
−11% · -13,8 kWh/m²/år
Work items
10
Financial payback
Comfort-led, not an investment: simple payback is long (54 år payback estimate). The value is a clearer sale, not a return.
  • Windows

    10 items

    11,9 m² · ≈-13,8 kWh/m²/år

    100.041 kr.-127.830 kr.

    View 10 work items
    • Udskiftning af eksisterende dannebrogsvinduer

      Vinduer · 3,5 m² · U 2,2 -> 0,8

      19.987 kr.-25.539 kr.

    • Udskiftning af eksisterende dannebrogsvinduer

      Vinduer · 1,6 m² · U 2,2 -> 0,8

      9.274 kr.-11.850 kr.

    • Udskiftning af eksisterende dannebrogsvinduer

      Vinduer · 1,3 m² · U 2,2 -> 0,8

      14.976 kr.-19.136 kr.

    • Udskiftning af eksisterende dannebrogsvinduer

      Vinduer · 1,2 m² · U 2,2 -> 0,8

      13.997 kr.-17.885 kr.

    • Udskiftning af eksisterende dannebrogsvinduer

      Vinduer · 1 m² · U 2,2 -> 0,8

      16.589 kr.-21.197 kr.

    • Udskiftning af eksisterende enkeltfagsvinduer i fast ramme

      Vinduer · 0,7 m² · U 2,8 -> 0,8

      6.966 kr.-8.901 kr.

    • Udskiftning af eksisterende enkeltfagsvinduer i fast ramme

      Vinduer · 0,6 m² · U 2,8 -> 0,8

      3.456 kr.-4.416 kr.

    • Udskiftning af eksisterende enkeltfagsvinduer i fast ramme

      Vinduer · 0,6 m² · U 2,8 -> 0,8

      3.402 kr.-4.347 kr.

    • Udskiftning af eksisterende dannebrogsvinduer

      Vinduer · 0,9 m² · U 2,2 -> 0,8

      5.184 kr.-6.624 kr.

    • Udskiftning af eksisterende enkeltfagsvinduer i fast ramme

      Vinduer · 0,6 m² · U 2,8 -> 0,8

      6.210 kr.-7.935 kr.

On your actual scan

The 14 windows, located on the 3D model.

Each green marker is a real window from the scan, fused with the Be18 energy proposal: the current U-value comes from the surface model, the target from the plan. Pick a floor and click a marker to read it.

Windows located
14
Glass area
19 m²
U-value
2,4 0,8 W/m²K
Floors
Basement (4) · Ground floor (8) · First floor (2)

3D inspection

Room evidence map

Ground floor · 8 annotations · 54 components

What it changes

Comfort first. The sale follows.

  1. 01

    Warmer in winter

    New windows cut heat loss at the largest openings in the house.

  2. 02

    Less label concern

    A bounded, costed path instead of vague label-D uncertainty at the viewing.

  3. 03

    Quieter rooms

    Sealed, modern glazing noticeably lowers street noise.

  4. 04

    Clearer disclosure

    The plan sits beside the inspection report, never instead of it.

Already on the register

There is already an open building permit.

Permit

S2025-2875

dated 14-04-2025

BBR records an open building case (S2025-2875) with a permit dated 14-04-2025 and construction logged for 2026. Stage this energy-upgrade plan around that work — windows, envelope and heating are cheapest to touch while the site is already open, and a single Byg-og-Miljø filing can carry both.

Source: BBR byggesager (construction_cases)

Why you can trust it

Every number traces to measured data.

Open evidence checklist →

Annex VIII readiness

6/12 ready

2 need review · 2 missing input · 2 rules pending.

Measured areas

Floor
155 m²
Wall
368 m²
Ceiling
177 m²

One honest caveat

This is a possible result from current energy data, not a certified future label until an energy expert reviews it. Heated area has a disclosed conflict .

Sources

4